ThermaGraph™ Data Center & HVAC Coolant

A ready-to-use graphene coolant in deionized water for closed-loop data center and HVAC cooling. A complete fill, not a top-off.

  • Patent pending
  • Made in the USA
  • Pre-mixed, never powder
Application
Indoor closed-loop data center cooling: CDU, direct-to-chip and rear-door heat exchanger loops. Also designed for closed-loop HVAC, such as chilled-water and hydronic heating and cooling loops, where freeze protection isn't required.
Carrier
Deionized water, with no glycol and no freeze package. A glycol build for freeze protection can be made on request.
Use
Ready to use as a complete fill, not a top-off. Graphene loading 0.5–1.5 wt%, stated on the COA. Higher loadings may be available on request (custom) if your system can take a denser fluid.
SKU
GI-TG-5GAL (5 gal pail)
GI-TG-55GAL (55 gal drum)
GI-TG-275GAL (275 gal tote)

Sizes: 5 gal pail, 55 gal drum, 275 gal tote

Request a quote for pricing, lead time and the right dose for your job.

Downloads

Patent pending. Made in the USA. Manufacturer: Graphene Integrations, Charlotte, NC.

About this product

ThermaGraph™ is supplied ready to use for compatible closed water loops, including direct-to-chip and suitable HVAC systems. It is a complete fill, not a glycol top-off. Confirm equipment compatibility and freeze-protection requirements before conversion. Obtain the current SDS, technical specification and lot documentation from GI. Pricing is by quote.

From heat-transfer performance to an efficient cooling loop

ThermaGraph™ is a complete water-based fill for suitable closed loops, with 0.5–1.5 wt% graphene in the supplied fluid—not a top-off dose. GI’s +6–18% higher convective heat-transfer coefficient versus a glycol baseline comes from internal pumped-loop tests. It is not independent field validation or an equivalent percentage electricity saving.

Turn that promising thermal result into a plant decision by comparing the same heat load and operating conditions. Log flow, inlet/outlet temperatures, pressure drop, pump, fan and chiller electricity; inspect filters, corrosion coupons and material compatibility. Water-based ThermaGraph is not a dielectric and must not immerse live electronics.

DOE’s liquid-cooling evaluation illustrates system-level metering; it did not test GI fluid. Assess environmental outcomes using measured kWh, the actual electricity mix, fluid manufacture, replacement, transport and disposal. Improved heat transfer is an opportunity to optimize the system, not a measured GI carbon footprint.

Research / measurement reference · Continue with the application guide