Graphene Case Studies: Test Results & Partner Projects

These case studies collect results Graphene Integrations has already published, each with a link to the full write-up. We publish results only when we have the data to back them.

Concrete: +67.7% compressive strength at 5% by weight of cement

Our liquid graphene concrete additive, validated at 5% by weight of cement (loading depends on mix design; see TDS), gave a +67.7% gain in compressive strength in independent third-party testing.

Graphene concrete additive · Press release: concrete strength results

Lubricants: up to 42% smaller four-ball wear-scar diameter, 26% higher weld load (Univar, Houston)

A graphene lubricant additive carried in oleic acid and monomer reduced four-ball wear-scar diameter by up to 42% and raised weld load by 26% in independent testing at Univar's Houston lab. Typical dosing is 1% to 7%.

Graphene lubricant additive · Press release: lubricant test results

Car care: four graphene products with ITW (Black Magic and Rain-X)

We worked with ITW's engineering team to develop four graphene-enhanced car care products, two for Black Magic and two for Rain-X, sold at major US auto parts and retail stores.

Read the ITW case study

Data center coolants: ThermaGraph™ +6% to +18% (internal testing results)

In internal testing results, ThermaGraph™ graphene coolant showed heat transfer gains of +6% to +18%. These are our own internal tests, not independent results.

Data center coolants

Armor composites with AARG

Graphene polymer composites for ballistic armor were developed with Advanced Armor Research Group (AARG) and evaluated with V50 ballistic testing.

AARG partnership

Request samples for your own trial · Graphene applications by industry

Concrete strength and embodied carbon

Cement is the binder in concrete. Its production releases CO₂ through limestone conversion and energy use, as explained by the IEA. That makes cement quantity an important part of a concrete carbon assessment.

GI’s additive achieved +67.7% compressive strength in third-party testing at the tested 5% supplied-additive dose by cement weight, not 5% pure graphene. This validated strength result supports investigating lower-cement mixes; it does not establish how much cement can be removed. Candidate mixes must meet the same required performance.

Conditional example: if 100 kg of Portland cement is actually avoided at the same required performance, gross avoided cement A1–A3 impact is 100 × 0.919 = 91.9 kg CO₂e. The 100 kg is an example assumption, not a reduction demonstrated by GI. The official US industry-average Portland cement EPD, revised July 2026, Table 4, gives 0.919 kg CO₂e/kg using 2019 production data, covering A1–A3, raw materials through manufacturing—not a current-year plant measurement or whole-life concrete footprint. CO₂e means carbon dioxide equivalent.

This is gross avoided cement-production impact, not measured GI net savings. Net savings require matched-performance mix validation and a consistent lifecycle comparison including additive manufacture, carrier, packaging, transport and all changed mix inputs. Unknown additive impacts are not zero. The strength result does not automatically establish cement reduction, longer service life or carbon capture.

Explore the concrete and embodied-carbon guide.

Choose evidence for the product you are developing

Match the evidence to the application: a lubricant wear-scar result, a water-loop heat-transfer result and a concrete strength result answer different questions. Compare your own formulation at the required performance, then measure energy, material use and service needs, including additive and carrier impacts.

Application testing and environmental assessment · Lubricant test evidence · ThermaGraph / ThermaGraph-D · Concrete and embodied carbon