AI racks have outgrown the air that used to cool them. The fluid in the loop now matters as much as the hardware around it. This book explains how heat leaves a data hall, how liquid-cooling loops and coolants actually work, and how to evaluate a graphene coolant without confusing a laboratory coefficient with a utility bill. In Graphene Integrations' internal pumped-loop laboratory tests, ThermaGraph showed a 6% to 18% higher convective heat-transfer coefficient than a glycol baseline. These are internal testing results — lab data — not an equivalent percentage saving in electricity, and not a field result. Site-scale dollar figures in these pages are modeled estimates. The book grew out of a presentation to about 250 data center engineers at one of the world's largest cloud providers, organized across five groups: Data Hall Design, Construction, Operations, Engineering, and Build Engineering Services.
Now available on Amazon as a Kindle edition. The paperback is coming soon.
Buy the Kindle edition — $11.99 Paperback coming soon
Librarians, teachers, reviewers and podcast hosts can request a complimentary review copy or an interview through our contact page or at sales@grapheneintegrations.com.
What’s inside
- Every Watt Becomes Heat
- When Air Is Not Enough
- A Short History of Taking Heat Away
- The Anatomy of a Data Center
- Heat, in Plain Words
- Liquid Options: From the Door to the Tank
- Coolant Chemistry: Water, Glycol, and Dielectrics
- What Graphene Is Supposed to Do in a Fluid
- ThermaGraph and ThermaGraph-D
- Two Questions in a Meeting
- PUE, Water, and the Energy Bill
- Modeled Savings at 20 MW and 100 MW
- Safety, Data Sheets, and Leaks
- Retrofit or New Build
- Maintenance, Monitoring, and a 30-Day Pilot
- HVAC and Other Closed Loops
- Water, Carbon, and the Strain on the Grid
- Buying, Specifying, and What Comes Next
Plus a glossary, a calculation worksheet, an FAQ for facility engineers, and further reading.
About the author
Frans Alkemade is the founder and CEO of Graphene Integrations, a US graphene manufacturer based in Charlotte, North Carolina, and founder/CEO of sister company Nano Technology Chemicals (NTC), a chemical distributor and toll blender. Before founding Graphene Integrations, he served as Director of Apple iMac Operations.
Contact: sales@grapheneintegrations.com · grapheneintegrations.com
Location: Charlotte, North Carolina
Cite or link to this book
Suggested citation (APA): Alkemade, F. (2026). Cooling the AI data center: Fluids, loops and graphene. Graphene Integrations. https://grapheneintegrations.com/cooling-the-ai-data-center
Frequently asked questions
Who wrote Cooling the AI Data Center?
Frans Alkemade, founder and CEO of Graphene Integrations, a US graphene manufacturer, and former Director of Apple iMac Operations.
Where can I buy it?
The Kindle edition is for sale on Amazon for $11.99. The paperback is coming soon.
What is the ThermaGraph result discussed in the book?
In Graphene Integrations' internal pumped-loop laboratory tests, ThermaGraph showed a 6% to 18% higher convective heat-transfer coefficient than a glycol baseline. These are internal testing results, not an equivalent percentage saving in electricity, and not a field result.
Who is it for?
Data-center engineers, facility operators, and anyone who needs to evaluate liquid-cooling loops and coolants, including graphene coolants, without confusing a laboratory coefficient with a utility bill.
